Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
2.
BMC Ophthalmol ; 21(1): 258, 2021 Jun 11.
Artículo en Inglés | MEDLINE | ID: covidwho-1266480

RESUMEN

BACKGROUND: During the coronavirus disease 2019 (COVID-19) epidemic, due to the traffic blockade and the shortage of medical resources, more and more premature infants could not receive timely and effective ROP screening, which delayed treatment and even caused children blindness. Therefore, how to carry out ROP screening safely and effectively during the epidemic was very important and urgent. This study aimed to evaluate the safety and feasibility of ROP screening assisted by telemedicine network during COVID-19 outbreak. METHODS: This retrospective study was conducted at Wuhan Children's hospital in Wuhan, China, from January to October, 2020. The measures which were performed to make the ROP screening more safe and effective were summarized and the comparison between ROP screening assisted by telemedicine network in 2020 and usual screening in 2019 were analyzed. RESULTS: A total of 267 outpatient infants completed ROP screening. The median gestational age was 32 weeks (30w to 34w) and the median birth weight was 1780 g (1460 g to 2100 g). Meanwhile, 149 (55.8%) out of 267 infants were males. During January to May in 2020, 86 screening appointments were received, among which 67 (77.9%) were from telemedicine platform online. The completing percentage of total online ROP appointments was higher than that of total face-to-face appointments (58.1% VS 22. 1%, P = 0.018). As for the number of infants screened between 2020 and 2019 from Februaryto October, 54 infants completed ROP screening in 2020, which was higher than that (51participants) in 2019 on September. Furthermore, compared with the usual screening in 2019, ROP screening assisted by telemedicine network in 2020 had smaller gestational age (32w VS 33w, p<0.001) and lower birth weight (1780 g VS 1900 g, p = 0.001). However, of the 267 infants screened, 18(6.7%) had ROP while the percentage of ROP screened in 2019 was the same (44[6.7%]). During follow-up, none of medical staffs was infected and no adverse reaction was reported. CONCLUSIONS: The screening for retinopathy of prematurity assisted by telemedicine network was safe and feasible during the COVID-19 pandemic. Preventive measures before and after screening were very necessary, which could effectively avoid cross infection.


Asunto(s)
COVID-19 , Retinopatía de la Prematuridad , Telemedicina , Niño , China/epidemiología , Estudios de Factibilidad , Femenino , Edad Gestacional , Humanos , Lactante , Recién Nacido , Masculino , Tamizaje Neonatal , Pandemias , Retinopatía de la Prematuridad/diagnóstico , Retinopatía de la Prematuridad/epidemiología , Estudios Retrospectivos , Factores de Riesgo , SARS-CoV-2
3.
World J Pediatr ; 17(3): 253-262, 2021 06.
Artículo en Inglés | MEDLINE | ID: covidwho-1176425

RESUMEN

BACKGROUND: Coronavirus disease 2019 (COVID-19) caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is an emerging disease. The consequences of SARS-CoV-2 exposure in infants remain unknown. Therefore, this study aims to investigate whether neonates born to mothers with COVID-19 have adverse brain development. METHODS: This multicenter observational study was conducted at two designated maternal and children's hospitals in Hubei Province, mainland China from February 1, 2020 to May 15, 2020. Neonates born to mothers with COVID-19 were enrolled. Brain magnetic resonance imaging (MRI) findings, and volumes of grey and white matters, and physical growth parameters were observed at 44 weeks corrected gestational age. RESULTS: Of 72 neonates born to mothers with COVID-19, 8 (11%) were diagnosed with COVID-19, 8 (11%) were critically ill, and no deaths were reported. Among the eight neonates that underwent brain MRI at corrected gestational age of 44 weeks, five neonates were diagnosed with COVID-19. Among these five neonates, three presented abnormal MRI findings including abnormal signal in white matter and delayed myelination in newborn 2, delayed myelination and brain dysplasia in newborn 3, and abnormal signal in the bilateral periventricular in newborn 5. The other three neonates without COVID-19 presented no significantly changes of brain MRI findings and the volumes of grey matter and white matter compared to those of healthy newborns at the equivalent age (P > 0.05). Physical growth parameters for weight, length, and head circumference at gestational age of 44 weeks were all above the 3rd percentile for all neonates. CONCLUSIONS: Some of the neonates born to mothers with COVID-19 had abnormal brain MRI findings but these neonates did not appear to have poor physical growth. These findings may provide the information on the follow-up schedule on the neonates exposed to SARS-CoV-2, but further study is required to evaluate the association between the abnormal MRI findings and the exposure to SARS-CoV-2.


Asunto(s)
Encéfalo/anomalías , Encéfalo/diagnóstico por imagen , COVID-19/transmisión , Transmisión Vertical de Enfermedad Infecciosa , Imagen por Resonancia Magnética , COVID-19/epidemiología , China/epidemiología , Femenino , Humanos , Recién Nacido , Masculino , Pandemias , Embarazo , SARS-CoV-2
4.
World J Pediatr ; 17(2): 171-179, 2021 04.
Artículo en Inglés | MEDLINE | ID: covidwho-1141519

RESUMEN

BACKGROUND: We collected neonatal neurological, clinical, and imaging data to study the neurological manifestations and imaging characteristics of neonates with coronavirus disease 2019 (COVID-19). METHODS: This case-control study included newborns diagnosed with COVID-19 in Wuhan, China from January 2020 to July 2020. All included newborns had complete neurological evaluations and head magnetic resonance imaging. We normalized the extracted T2-weighted imaging data to a standard neonate template space, and segmented them into gray matter, white matter, and cerebrospinal fluid. The comparison of gray matter volume was conducted between the two groups. RESULTS: A total of five neonates with COVID-19 were included in this study. The median reflex scores were 2 points lower in the infected group than in the control group (P = 0.0094), and the median orientation and behavior scores were 2.5 points lower in the infected group than in the control group (P = 0.0008). There were also significant differences between the two groups in the total scale score (P = 0.0426). The caudate nucleus, parahippocampal gyrus, and thalamus had the strongest correlations with the Hammersmith neonatal neurologic examination (HNNE) score, and the absolute correlation coefficients between the gray matter volumes and each part of the HNNE score were all almost greater than 0.5. CONCLUSIONS: We first compared the neurological performance of neonates with and without COVID-19 by quantitative neuroimaging and neurological examination methods. Considering the limited numbers of patients, more studies focusing on the structural or functional aspects of the virus in the central nervous system in different age groups will be carried out in the future.


Asunto(s)
COVID-19/diagnóstico por imagen , Imagen por Resonancia Magnética , Neuroimagen/métodos , Neumonía Viral/diagnóstico por imagen , Biomarcadores/sangre , COVID-19/epidemiología , Estudios de Casos y Controles , Desarrollo Infantil , China/epidemiología , Femenino , Humanos , Recién Nacido , Transmisión Vertical de Enfermedad Infecciosa , Masculino , Examen Neurológico , Neumonía Viral/epidemiología , Neumonía Viral/virología , SARS-CoV-2
5.
Pediatr Pulmonol ; 56(6): 1419-1426, 2021 06.
Artículo en Inglés | MEDLINE | ID: covidwho-1130673

RESUMEN

BACKGROUND: Lung ultrasound (LUS) and lung ultrasound score (LUSS) have been successfully used to diagnose neonatal pneumonia, assess the lesion distribution, and quantify the aeration loss. The present study design determines the diagnostic value of LUSS in the semi-quantitative assessment of pneumonia in coronavirus disease 2019 (COVID-19) neonates. METHODS: Eleven COVID-19 neonates born to mothers with COVID-19 infection and 11 age- and gender-matched controls were retrospectively studied. LUSS was acquired by assessing the lesions and aeration loss in 12 lung regions per subject. RESULTS: Most of the COVID-19 newborns presented with mild and atypical symptoms, mainly involving respiratory and digestive systems. In the COVID-19 group, a total of 132 regions of the lung were examined, 83 regions (62.8%) of which were detected abnormalities by LUS. Compared with controls, COVID-19 neonates showed sparse or confluent B-lines (83 regions), disappearing A-lines (83 regions), abnormal pleural lines (29 regions), and subpleural consolidations (2 regions). The LUSS was significantly higher in the COVID-19 group. In total, 49 regions (37%) were normal, 73 regions (55%) scored 1, and 10 regions (8%) scored 2 by LUSS. All the lesions were bilateral, with multiple regions involved. The majority of the lesions were located in the bilateral inferior and posterior regions. LUS detected abnormalities in three COVID-19 neonates with normal radiological performance. The intra-observer and inter-observer reproducibility of LUSS was excellent. CONCLUSIONS: LUS is a noninvasive, convenient, and sensitive method to assess neonatal COVID-19 pneumonia, and can be used as an alternative to the use of diagnostic radiography. LUSS provides valuable semi-quantitative information on the lesion distribution and severity.


Asunto(s)
COVID-19/diagnóstico por imagen , Pulmón/diagnóstico por imagen , SARS-CoV-2 , Femenino , Humanos , Recién Nacido , Masculino , Reproducibilidad de los Resultados , Estudios Retrospectivos , Ultrasonografía
6.
Aging (Albany NY) ; 12(17): 16672-16674, 2020 Sep 11.
Artículo en Inglés | MEDLINE | ID: covidwho-761184

RESUMEN

Pregnant women are susceptible population of COVID-19 which are more likely to have complications and even progress to severe illness. Pregnancy with COVID-19 and neonates are rarely reported. We report a newborn with normal IgM and elevated IgG antibodies born to an asymptomatic infection mother with COVID-19. We assessed whether there was intrauterine vertical transmission potential of COVID-19.

8.
Front Pediatr ; 8: 104, 2020.
Artículo en Inglés | MEDLINE | ID: covidwho-51673

RESUMEN

A novel viral respiratory disease caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), is responsible for an epidemic of the coronavirus disease 2019 (COVID-19) in cases in China and worldwide. Four full-term, singleton infants were born to pregnant women who tested positive for COVID-19 in the city of Wuhan, the capital of Hubei province, China, where the disease was first identified. Of the three infants, for who consent to be diagnostically tested was provided, none tested positive for the virus. None of the infants developed serious clinical symptoms such as fever, cough, diarrhea, or abnormal radiologic or hematologic evidence, and all four infants were alive at the time of hospital discharge. Two infants had rashes of unknown etiology at birth, and one had facial ulcerations. One infant had tachypnea and was supported by non-invasive mechanical ventilation for 3 days. One had rashes at birth but was discharged without parental consent for a diagnostic test. This case report describes the clinical course of four live born infants, born to pregnant women with the COVID-19 infection.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA